Set the terminal as follows: Baud rate 19200, 8 data bits, No parity, No start bit, 1 stop bit, Flow control Xon/Xoff
Press the ‘Return key (<CR>) and the terminal window should echo a ‘
>
if communication is established. To fix the
IP address type the following:
ip
<CR>
setip nnn nnn nnn nnn
<CR> where ‘nnn...’ is the IP address, e.g. ‘10 1 1 1 10’.
setmask nnn nnn nnn nnn
<CR> where ‘nnn...’ is the subnet mask, e.g. ‘255 255 255 0’.
Note that this should match other devices local to the console.
setgate nnn nnn nnn nnn
<CR> where ‘nnn...’ is the gateway address e.g. ‘10 1 1 1’